ARDS Driving Pressure: Plateau, PEEP and Worked Examples
Calculate driving pressure and compliance in ARDS, distinguish plateau from peak pressure, and understand the limits of a familiar EDAIC formula.

For a passive patient under suitable measurement conditions, respiratory-system driving pressure is plateau pressure minus total PEEP. It is the pressure change associated with the delivered tidal volume. The formula is easy; knowing when its inputs are meaningful is the part worth learning for EDAIC.
Driving pressure is not peak inspiratory pressure, not a direct measurement of lung tissue stress, and not an isolated instruction to change a ventilator setting. Start by identifying which pressure you have actually measured.
Separate the pressures before calculating
| Variable | What you are describing | Common reasoning error |
|---|---|---|
| Peak airway pressure | Pressure during inspiratory flow | Treating it as purely elastic pressure |
| Plateau pressure | A no-flow inspiratory measurement under appropriate conditions | Ignoring patient effort or an inadequate pause |
| Total PEEP | End-expiratory pressure including intrinsic PEEP | Assuming it always equals the set value |
| Driving pressure | Plateau minus total PEEP in the simplified passive model | Subtracting PEEP from the peak pressure |
Airway resistance and respiratory-system elastic properties contribute differently to the pressure trace. The joint ATS/ESICM/SCCM guideline defines plateau pressure using an inspiratory pause, rather than substituting peak pressure. Also distinguish the combined lung-and-chest-wall system from the lung alone: airway pressure is not synonymous with transpulmonary pressure. Joint ventilation guideline
Try 10 EDAIC questions free
Create a free account and answer EDAIC-style Part 1 MTF questions — each one graded per statement, with a full explanation.
Worked example 1: the straightforward calculation
An invented exam stem specifies passive ventilation, a valid inspiratory hold, no leak and a total PEEP measurement. Tidal volume is 420 mL, plateau pressure 27 cm H₂O, and total PEEP 12 cm H₂O.
Driving pressure = 27 − 12 = 15 cm H₂O.
Using the simplified static relationship:
Respiratory-system compliance = 420 ÷ 15 = 28 mL/cm H₂O.
State the units. If you enter tidal volume as 0.42 L, the answer becomes 0.028 L/cm H₂O: the same result expressed differently, not a thousand-fold physiological change.
Now imagine that peak pressure was 36 cm H₂O. Substituting it for plateau would produce 24 cm H₂O and an apparent compliance of 17.5 mL/cm H₂O. The arithmetic is internally consistent, but it answers the wrong measurement question. Good exam technique includes checking the label on every input before calculating.
Worked example 2: why the PEEP label matters
Use the same plateau pressure of 27 cm H₂O. The machine's set PEEP is 8 cm H₂O, but measured total PEEP is 12 cm H₂O.
Subtracting set PEEP gives 19 cm H₂O; subtracting total PEEP gives 15 cm H₂O. In this hypothetical passive calculation, the latter is the relevant value. The four-point difference comes from an assumption, not from rounding.
An examiner may ask why this matters. Explain that a valid equation can produce a misleading result when the variable entered is only a convenient substitute for the variable defined. This is a general lesson that also applies to arterial pressure and pharmacokinetic calculations.
Answer an EDAIC-style question
This is one exam-format Part 1 multiple-true-false question from our bank. Mark each statement true or false, then see the worked answer.
Regarding the pathophysiology of oxygen delivery and consumption in circulatory shock:
Mark each statement true or false:
In healthy adults at rest, systemic oxygen delivery is approximately 1000 mL/min while oxygen consumption is about 250 mL/min, creating a physiological oxygen reserve.
When systemic oxygen delivery decreases, oxygen consumption immediately falls in direct proportion, indicating supply dependency at all levels of DO₂.
Cardiac output is determined by the product of heart rate and stroke volume, with stroke volume being influenced by preload, afterload, and myocardial contractility.
The unifying feature of all forms of shock, regardless of aetiology, is acute circulatory failure associated with inadequate cellular oxygen utilisation.
In septic shock, early goal-directed therapy targeting supranormal oxygen delivery values has been shown to consistently reduce mortality across all patient populations.
Association is not a complete treatment algorithm
Amato and colleagues analysed data from previous ARDS trials and found a strong association between driving pressure and survival. That influential analysis sharpened attention on tidal volume relative to the available respiratory-system compliance. It did not randomise every patient to a universal driving-pressure target, so it cannot justify promising that lowering one displayed number will independently improve an individual's outcome. Amato et al.
The ATS guideline retains a broader lung-protective approach and addresses PEEP and other interventions in defined ARDS settings. Read its recommendations as a package with populations and evidence certainty attached. Do not reduce them to “more PEEP is always better,” or use a favourable change in driving pressure as the only endpoint. ATS guideline
What changes when the patient is breathing?
Spontaneous effort complicates interpretation. A pressure displayed at the airway does not necessarily capture the full pressure generated across the lung. Research has investigated driving-pressure measurement during assisted ventilation, but applicability depends on measurement technique and the patient's interaction with the ventilator. Do not carry the passive worked example into every assisted breath without reconsidering its assumptions. Assisted-ventilation study
For a viva, an explicit limitation is a strength: “I can calculate a number, but first I would establish whether the conditions make that number interpretable.” That is more precise than either refusing to calculate or presenting a value with unjustified certainty.
Self-test: explain the false statement
“A high peak pressure always proves low compliance.” False: peak pressure includes a flow-related resistive component.
“Driving pressure of 15 cm H₂O proves ventilation is safe.” False: an isolated value is not a guarantee, and measurement validity, regional mechanics and other clinical factors remain relevant.
“The same tidal volume can produce different driving pressures.” True: the relationship depends on the respiratory-system compliance in the stated model.
Review compliance versus airway resistance, then practise unit discipline with SI conversions. Use the Part II data-interpretation guide to explain the calculations aloud, or test the distinctions in the EDAIC question bank.
Sources and further reading
- American Thoracic Society guideline update on adult ARDS (2024)
- Amato et al. Driving pressure and survival in ARDS (2015)
- Bellani et al. Driving pressure during assisted ventilation in ARDS (2019)
- ATS/ESICM/SCCM mechanical ventilation guideline for adult ARDS (2017)
Prepared with AI assistance. Sources checked on 6 November 2026. Original teaching examples are hypothetical. This article supports exam revision and does not replace patient-specific assessment, local protocols or specialist advice.
Start preparing for EDAIC Part I
Syllabus-mapped lessons, 30,000 MTF questions, spaced-repetition flashcards and an AI study plan — in one platform.
Start free